Doorguard
Monitoring of Emergency Exit Doors
The comprehensive solution for all applications
The permanent protection of buildings against entry by
unauthorized persons as well as the uncontrolled exit of
a zone are basically contrary to the legal requirements
that demand that it must also be possible to exit a buil-
ding without hindrance in the event of an emergency.
The Doorguard that is now available on the market is a
product that not only fulfils both these requirements but
also has an attractive design and is flexible in use.
The units enable simultaneous control and monitoring of
the opening of emergency exit doors.
The Doorguard is available in two different versions with
varying connection technology:
- Doorguard for MB panels BUS-2
- Doorguard hardwired version
The Doorguard for MB panels BUS-2 is suitable for
integrating into BUS-2 networks with connection to an
intruder alarm control panel.
The Doorguard hardwired version is intended for self-suf-
ficient applications solely for monitoring emergency exit
doors without connection to an IACP.
The units can be easily installed on site.The operating
unit and alarm signalling device can be installed either
separately or as a combined unit to meet the specific
requirements of the building or application.
The door contacts (release contacts) at the doors that
require monitoring trigger the alarm.In the event of unaut-
horized opening of the emergency exit door, an acousti-
cal and optical signal is emitted on site.
Authorized opening
If the emergency exit door requires opening by an autho-
rized person, the monitoring of this door can be deacti-
vated by releasing.This enables authorized persons to
enter the building through the door once or several times
depending on the programming without triggering a
signal.
The release of the emergency exit door is indicated at
the operating unit via the green LED “Operating state”.
Release is possible directly at the unit via the half cylin-
der and/or the reader (for IK2 / IK3 ID data carriers) that
is integrated in the Doorguard for MB panels BUS-2.
• Monitoring of opening of emergency door exits
• Indication of operating state via LED
• Indication of triggering and “Door open”state
• Input for release contact (door contact)
• Input for tamper switch
• Installation possibility of a half cylinder as per
DIN 18252
• Alarm signalling device for remote mounting -
separate from the operating unit (e.g.above the door)
Common performance features - Doorguard
• Optical alarm signalling device with high-
performance LEDs
• Acoustical alarm signalling device with
piezo-electronic alarm device
• Resonance-optimized housing for extremely
loud radiation of alarm tone on all sides
• Cover and tear-off monitoring of alarm signalling
device and operating unit
• External operating input for remote operating
module (key-operated switch)

»»Ò³
Doorguard for MB panels BUS-2
BUS-2
Operating panel*
Release contact
Glass
breakage
detector
BUS-2
BUS-2
Control panel with BUS-2
e. g. IACP 561-MB100
Graphik user interface
TouchCenterBUS-2
Data carrier
Bolt switching contact
* Opening for half cylinder can be covered
with enclosed plate.
Latch contact
Alarmzentrale
561-MB100
Betrieb
S
Alarm
S
Storung
Info4
Info3
Info2
Info1
Pol.-Notruf
Uberfall
Sabotage
Einbruch
System-
Storung
0
1
2
3
M
E
G
F
B
A
4
5
6
7
8
9
U
B
E
R
F
A
L
L
F
U
N
K
T
I
O
N
S
O
N
D
E
R
F
U
N
K
T
I
O
N
Bereiche
wahlen/
ansehen
Meldungen
ansehen
Zusatz-
funktionen
Gruppen
ansehen/
sperren
Melder
ansehen/
sperren
Eingabe
Quittierung
Bedienende
ALARMSTOP
unscharf
loschen
Intern
scharf-
schalten
AUS
EIN
nein
ja
Pers.no.
Name
Alarm device
acoustic alarm and
optical alarm
External
key-operated switch
NOTAUSGANG
NurbeiGefahr
Nottasterbetatigen
The Doorguard for MB panels BUS-2 communicates
with the corresponding intruder alarm control panel
(561-MB24/48/100) via the BUS-2.Programming of
system data and projects as well as management of aut-
horization data for entering the door is carried out via the
programming software “WINFEM Advanced”of the intru-
der alarm control panel.Voltage for the Doorguard for MB
panels BUS-2 is supplied via the BUS-2 connection, thus
providing an optimum integration solution.
All functions and connections that are required for moni-
toring emergency exit doors are contained in this unit.
All messages are transmitted via the BUS-2 to the intru-
der alarm control panel.Release is possible directly at the
Doorguard for MB panels BUS-2 via the half cylinder
and/or the integrated reader (for IK2 / IK3 ID data carrier).
Remote release (activation (inactivation) is possible via
every operating keypad with disabling function and
display unit that is connected to the BUS-2 and via the
operating function “Disable detector groups”or a graphic
user interface.
The total number of Doorguard for MB panels BUS-2 units
that can be used depends on the possible number of swit-
ching devices of the IACP that is being used.Remote
release via the software program package IQ MultiAccess/
IQ SystemControl is also possible.
• Input for release contact
(e.g.door monitoring via latch contact)
• Input with clearing function for self-storing sensors
• Integrated reader for IK2 / IK3 ID data carriers
• Operation possible via half cylinder and/or integrated
reader (IK2/IK3) or the operating units of the IACP
• Operation at BUS-2 of the 561MB-24/48/100
intruder alarm control panel series
• Programming as integrated BUS user with
WINFEM Advanced
Performance features
• Integration into the room/time zone concept of the
intruder alarm control panel
• Use of operating modules via the BUS-2 of the
intruder control alarm panel as
- Operating and display keypad
(e.g.Item no.012542 or Item no.012577)
for inactivating or activating or
- 16-DG display module (e.g.Item no.012548)

»»Ò³
Doorguard hardwired version
This system unit combines all the functions that enable
the self-sufficient monitoring of emergency exit doors.
Contrary to the BUS-2 device, max.16 Doorguard hard-
wired versions units can be connected via a proprietary
Bus system.A16-DG disable and display keypad
(Item no.012542) or a 16-DG display module (Item no.
012548) can be used for remote individual indication of
the networked system units as a remote indicating panel
(Master/slave operation).
The modules have an optical indicator (2 LEDs) for
every connected Doorguard as well as a key (only Item
no.012542) for remote release (inactivation/activation).
An acoustical signal (collective alarm) is also emitted
when the emergency exit door is opened by an unautho-
rized person.
• Integrated energy-saving power supply unit for
230 V AC with low power consumption
• Operation possible per half cylinder and/or 16-DG
disable and display keypad
• Stand-alone solution for an emergency exit door
Performance features
• Master/Slave operation for the networking of max.
16 Doorguard hardwired version systems with:
- A 16-DG disable and display keypad
(Item no.012542) as an operating and display
keypad
- Or a 16-DG display module (Item no.012548)
as a display for status indication
Slave1
NOTAUSGANG
NurbeiGefahr
Nottasterbetatigen
230VAC
2
3
4
5
6
7
8
13
10
11
12
14
15
16
D
D
D
0V
+UB
0V
0V
0V
230VAC
230VAC
Alarm device
acoustic alarm and
optical alarm
Operating panel
(Master)
External
key-operated switch
Release contact
230VAC
16-DG disable and display keypad
Release contact
External key-operated switch
max. 15 slave devices
230VAC
Release contact
Red = Emergency exit door open
Yellow = Doorguard inactive
Key = Inactivation, activation
(only 012542)
External key-operated switch

»»Ò³
Honeywell Security Group
Novar GmbH
Joh.-Mauthe-Str.14 · D-72458 Albstadt
Phone+49(0)7431/801-0· Fax 801-1220
www.honeywell.com/security/de
info.security.de@honeywell.com
P02423-22-0G0-00
01.2010 ·Subject to change without notice.
©2010 Honeywell International Inc.
Order data
Item no.
Descripton
041450
Doorguard for MB panels BUS-2
System unit for monitoring emergency exit doors.
With integrated IK2 / IK3 reader.BUS-2 connection.
-Approval:pending
Without half cylinder
041460
Doorguard hardwired version
System unit for monitoring emergency exit doors.Conventional connection technology.
Without half cylinder
A
ccessor
ies
028032
Half cylinder
Technical Data
Item no.041450
Item no.041460
T
ec
hnical data - oper
ating unit
Mains voltage
230 V AC
Frequency
50 Hz
Power consumption standby
2,1 VA
Rated operating voltage
12 V DC
Operating temperature range
10 V DC tp 15 V DC
Current consumption
?
15 mA
Transponder reader technology
proX1/IK2, proX2/IK3
(without alternating code)
Transponder reading distance
max.3 cm
Half cylinder as per DIN 18252
Dimension A= 30 mm
Dimension A= 30 mm
Operating temperature range
-5 °C to +45 °C
-5 °C to +45 °C
Storage temperature range
-25 °C to +70 °C
-25 °C to +70 °C
Environmental Class as per VdS
II
II
Protection Class as per DIN 40 050
IP 40
IP40
Dimensions (W x H x D)
110 x 140 x 53 mm
110 x 140 x 53 mm
Housing colour
pure-white (similar to RAL 9010)
pure-white (similar to RAL 9010)
T
ec
hnical Data - alar
m de
vice
Operating temperature range
9 V DC to 15 V DC
Current consumption siren - int.tone
?
25 mA
- cont.tone
?
50 mA (only BUS-2 device)
Loudness level
approx.100 dBA
Current consumption - flash lamp
?
25 mA
Flash lamp LED - flash interval
approx.1,5 Hz
Operating temperature range
-5 °C to +45 °C
Storage temperature range
-25 °C to +70 °C
Environmental Class as per VdS
II
Protection Class as per DIN 40 050
IP 40
Dimensions (W x H x D)
110 x 103 x 53 mm
Housing colour
pure-white (similar to RAL 9010)
See product catalogue for further data.