Product Data Sheet
IMPORTANT
•
Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
•
It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Bottom entry conduit location
Stator bar ‘dead area’ barrier
Fixing locations
Straight bar rotor
Floor Anchors to be drilled during
installation, 12mm dia x 100mm deep.
Concrete Base to BS 5328:1997
specification. Base to be flat and
level to +/- 5mm over footprint
area. Dimensions to be > 1800 x
3300 x 150 deep min.
Site Preparation RotaSec MD120F
(Shown with straight bar rotor)

ปปาณ
……………………………………….……...……………….
………………………………………………………………..
PDS/RotaSec M Site Prep/Issue 1 02.01
2
Product Data Sheet
IMPORTANT
•
Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
•
It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Bottom entry conduit location
Stator bar ‘dead area’ barrier
Fixing locations
Straight bar rotor
Floor Anchors to be drilled during
installation, 12mm dia x 100mm deep.
Concrete Base to BS 5328:1997
specification. Base to be flat and
level to +/- 5mm over footprint
area. Dimensions to be > 1800 x
3300 x 150 deep min.
Site Preparation RotaSec MD90F
(Shown with straight bar rotor)

ปปาณ
……………………………………….……...……………….
………………………………………………………………..
PDS/RotaSec M Site Prep/Issue 1 02.01
3
Product Data Sheet
Site Preparation RotaSec MD120R
(Shown with straight bar rotor)
IMPORTANT
•
Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
•
It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Bottom entry conduit location
Stator bar ‘dead area’ barrier
Fixing locations
Straight bar rotor
Floor Anchors to be drilled during
installation, 12mm dia x 100mm deep.
Concrete Base to BS 5328:1997
specification. Base to be flat and
level to +/- 5mm over footprint
area. Dimensions to be > 1800 x
3300 x 150 deep min.
GRP canopy
Walkway down lights
Rain water down pipe

ปปาณ
……………………………………….……...……………….
………………………………………………………………..
PDS/RotaSec M Site Prep/Issue 1 02.01
4
Product Data Sheet
Site Preparation RotaSec MD90R
(Shown with straight bar rotor)
IMPORTANT
•
Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
•
It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Bottom entry conduit location
Fixing locations
Straight bar rotor
Floor Anchors to be drilled during
installation, 12mm dia x 100mm deep.
Concrete Base to BS 5328:1997
specification. Base to be flat and
level to +/- 5mm over footprint
area. Dimensions to be > 1800 x
3300 x 150 deep min.
GRP canopy
Walkway down lights
Rain water down pipe
Stator bar ‘dead area’ barrier

ปปาณ
……………………………………….……...……………….
………………………………………………………………..
PDS/RotaSec M Site Prep/Issue 1 02.01
5
Product Data Sheet
Site Preparation RotaSec MD120S
(Shown with straight bar rotor)
IMPORTANT
•
Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
•
It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Bottom entry conduit location
Stator bar ‘dead area’ barrier
Fixing locations
Straight bar rotor
Floor Anchors to be drilled during
installation, 12mm dia x 100mm deep.
Concrete Base to BS 5328:1997
specification. Base to be flat and
level to +/- 5mm over footprint
area. Dimensions to be > 1800 x
3300 x 150 deep min.
GRP canopy
Walkway down lights
Rain water down pipe
GRP side cabinets

ปปาณ
……………………………………….……...……………….
………………………………………………………………..
PDS/RotaSec M Site Prep/Issue 1 02.01
6
Product Data Sheet
Site Preparation RotaSec MD120S
(Shown with straight bar rotor)
IMPORTANT
•
Any horizontal pipe or conduit runs below the RotaSec must be at least 140mm below FFL.
•
It is the customers responsibility to ensure the structural integrity and strength of the installation location.
Bottom entry conduit location
Stator bar ‘dead area’ barrier
Fixing locations
Straight bar rotor
Floor Anchors to be drilled during
installation, 12mm dia x 100mm deep.
Concrete Base to BS 5328:1997
specification. Base to be flat and
level to +/- 5mm over footprint
area. Dimensions to be > 1800 x
3300 x 150 deep min.
GRP canopy
Walkway down lights
Rain water down pipe
GRP side cabinets

ปปาณ